Chapter 5 Viewing Properties and Modifying Settings
Modifying Unit Settings
62 LanScaperPRO Network Tester User’s Guide
3 Press the SEL key.
The Calibrate Length screen appears.
Figure 30 Calibrate Length screen
4 Remove all cables from the tester, as directed by the
screen.
5 Press the TEST key or press any other key to exit.
If the TEST key is pressed, the tester runs the cali-
bration routine, stores the value, and returns the user
to the Setup menu.
Finding a
length constant
The Find Length Constant screen allows for the measure-
ment of the length constant of an attached known length
of cable. It is recommended that at least 50 feet of cable
be used to minimize the resolution error. (1 foot in 50 = 2%
uncertainty).
NOTE
The effect of a patch cable on the measured length of a
cable run can be eliminated by leaving the patch cable
attached to the tester while calibrating cable length.
LanScaperPRO_User_Guide.book Page 62 Friday, January 25, 2008 1:14 PM