If there was an error, the results are displayed
for twice as long.
If the lights for the pairs expected are on, the
cable is good.
Debug Mode (See “Ethernet Up-Link Cable
Example”) The debug mode is provided to allow
diagnosis of faults, especially when there are
multiple errors on multiple pairs. To enter the
debug mode, press and hold the tone button
until all lights on the main unit light (lamp test).
Once the lamp test is complete, debug displays
the results of the last cable test. This is from
internal memory, so the cable is not required to
be connected when running debug.
The debug display begins with a short flash on
the 1-2 pair to indicate that what follows is the
result for the 1-2 pair test (or the “from”). If the
pair was not open, a second longer flash on
one or more pair lights designates what pair 1-
2 is connected “to” at the remote end, or pairs
involved in a fault condition along with the fault
lights. The 3-6, 4-5 and 7-8 pair lights each in
turn begin with a short flash followed by the
results for that pair. The individual pair results
continue to be displayed until the tone button
is pressed again or two complete cycles of all
pairs is completed. The remote unit does not
display anything when in debug mode.